SID conversion for InfoObject &1
Message type: E = Error
Message class: RSRV -
Message number: 357
Message text: SID conversion for InfoObject &1
Checking SIDs for InfoObject 0UNIT
within valid interval limits. The interval limits are determined by the
number range object BIM9999996.
If the SID values lie below the interval limits, correct this
situation by executing a repair. The repair for SID table entries in
InfoObject 0UNIT proceeds as follows:
Conversion of SID table entries for InfoObject 0UNIT
Modification of SID entries in the unit dimensions of ALL InfoCubes
Possible reconstruction of tables for defined hierarchies for
InfoObject 0UNIT.
If the SID values lie within the interval limits, no conversion
is necessary. However, a simulation run that describes or checks
possible conversions of entries is started.
If the SID values lie under, over, within and over, or within and under
the interval limits this test provides no means of repair. In this case,
please contact SAP.
To avoid errors occurring in the BW system, do not execute BW functions
during a repair (staging and reporting in particular).
If an error occurs during a repair, the BW system may be in an
inconsistent state as a result. Take note of the error message in the
log and if necessary remove the cause of the error. A successful
repair is confirmed with the message "SID conversion for
InfoObject 0UNIT completed successfully".
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
This test checks whether the entries in the SID table for 0UNIT liewithin valid interval limits. The interval limits are determined by the
number range object BIM9999996.
If the SID values lie below the interval limits, correct this
situation by executing a repair. The repair for SID table entries in
InfoObject 0UNIT proceeds as follows:
Conversion of SID table entries for InfoObject 0UNIT
Modification of SID entries in the unit dimensions of ALL InfoCubes
Possible reconstruction of tables for defined hierarchies for
InfoObject 0UNIT.
If the SID values lie within the interval limits, no conversion
is necessary. However, a simulation run that describes or checks
possible conversions of entries is started.
If the SID values lie under, over, within and over, or within and under
the interval limits this test provides no means of repair. In this case,
please contact SAP.
To avoid errors occurring in the BW system, do not execute BW functions
during a repair (staging and reporting in particular).
If an error occurs during a repair, the BW system may be in an
inconsistent state as a result. Take note of the error message in the
log and if necessary remove the cause of the error. A successful
repair is confirmed with the message "SID conversion for
InfoObject 0UNIT completed successfully".
Error message extract from SAP system. Copyright SAP SE.